Zeta Rod reaction chambers

Reaction chambers are constructed of PVC or CPVC, and are lined with stainless steel. Reaction chambers are used when:

  • Exising piping is of too small a diameter (less than 3 inches ID) to accept a Zeta Rod electrode,
  • Piping is non-metallic,
  • The physical layout of the water systems prevents the installation of a Zeta Rod electrode into an elbow or tee.

The liner of the reaction chamber is connected to a lug on the outside of the chamber. This lug is connected to a good earth ground so that the full voltage of the power supply is developed between the Zeta Rod electrode and the stainless steel lining in the chamber.

Reaction chamber.

Reaction Chamber Dimensions:

ModelElectrode ModelMaterialDimension ADimension C
ZR200ZR18SSchedule 80 PVC57.2 cm
22.5"
11.4 cm
4.5"
ZR200HTZR18SSched 80 CPVC67.3 cm
26.5"
11.4 cm
4.5"
ZR300ZR24SSched 80 PVC72.4 cm
28.5"
11.4 cm
4.5"
ZR300HTZR24SSched 80 CPVC82.6 cm
32.5"
11.4 cm
4.5"
ZR400ZR36SSched 80 PVC119.4 cm
47.0"
19.1 cm
7.5"